Vega Capacitive electrodes EK Profibus PA Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Vega Capacitive electrodes EK Profibus PA. VEGA Capacitive electrodes EK Profibus PA User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Level and Pressure
Operating Instructions
Capacitive electrodes EK
Profibus PA
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - Operating Instructions

Level and PressureOperating InstructionsCapacitive electrodes EKProfibus PA

Page 2 - Note Ex area

10 Capacitive electrodes EK - Profibus PA321EK 21 up to 6 bartemperatureadapterEK 24:from 100°C 6 bar,max. 150°C for30 min.Product descriptionPEPTFEFE

Page 3 - Contents

Capacitive electrodes EK - Profibus PA 111)Ambient temperature on the oscillatorProduct descriptionElectronics temperatureProduct and ambient temperat

Page 4 - 1 Product description

12 Capacitive electrodes EK - Profibus PAProduct description1.4 ApprovalsExplosion protectionOnly certified EK** Ex 0 capacitive electrodesmay be used

Page 5 - 1.2 Types and versions

Capacitive electrodes EK - Profibus PA 13Type EK 31 (partlyinsulated)L (min. 400 mm, max. 20000 mm)Product description1.5 DimensionsTyp EK 21 (fully i

Page 6

14 Capacitive electrodes EK - Profibus PAProduct descriptionHousing Temperature adapterhousing of plastic/AluminiumConcentric tube Screening tubeof 1.

Page 7 - 1.3 Technical data

Capacitive electrodes EK - Profibus PA 15ser. no. 10612892Product description1.6 Type plateBefore mounting and electrical connection,please make sur

Page 8

16 Capacitive electrodes EK - Profibus PAMountingLateral load2 Mounting2.1 Mounting instructionsGeneralDifferent mediums and measurementrequirements m

Page 9 - Varying moisture content

Capacitive electrodes EK - Profibus PA 17MountingShortening the electrodeHumidityTo avoid fraying the steel cable (EK 31)during cutting, you must tin

Page 10 - and operating

18 Capacitive electrodes EK - Profibus PACable electrod in solidsMountingFixingweightContinuous electrodesLNon-conductive vesselIn non-conductive vess

Page 11 - Temperature class T3

Capacitive electrodes EK - Profibus PA 19dd d 6 d 6MountingFillingEmptyingMaterial cone, filling and emptying centeredd312 d 10Filling Emptying1 Emp

Page 12 - 1.4 Approvals

2 Capacitive electrodes EK - Profibus PASafety information, Note Ex areaSafety informationPlease rfead this manual carefully, and alsotake note of cou

Page 13 - 1.5 Dimensions

20 Capacitive electrodes EK - Profibus PAElectrical connection3 Electrical connection3.1 Connection instructionsNoteSwitch off the power supply before

Page 14 - Housing Temperature adapter

Capacitive electrodes EK - Profibus PA 21-+ESCOKTank 1m (d)12.34512 5678PROFIBUS+-EEx ia IICsee certificateon87654321RSENSORDISPLAY1234 56 78Electrica

Page 15 - Z-65.13.XXX

22 Capacitive electrodes EK - Profibus PAElectrical connectionQualified personnelInstruments which are operated in Ex areasmust only be connected by q

Page 16 - 2 Mounting

Capacitive electrodes EK - Profibus PA 23Profibus PA in Ex environmentFor application in Ex areas, the PA bus andall connected instruments must be cer

Page 17 - Metal vessel

24 Capacitive electrodes EK - Profibus PAElectrical data of the cablesRDCno. of A in Z31.25kHzC in damping screencores mm2nF/kmSINEC 6XV1 44 Ω/km 2 0.

Page 18 - Lateral mounting

Capacitive electrodes EK - Profibus PA 25Electrical connection+E1-E2+A1+A2-B62-30 WINOUT12 5678PROFIBUS+-EEx ia IICsee certificateon87654321Rcarrier r

Page 19 - Material cone

26 Capacitive electrodes EK - Profibus PAElectrical connectionWiring example for the installation of an Ex system on vessels without cathodiccorrosion

Page 20 - 3 Electrical connection

Capacitive electrodes EK - Profibus PA 27Electrical connectionWiring example for the installation of an Ex system on vessels with cathodiccorrosion pr

Page 21 - VEGADIS 50

28 Capacitive electrodes EK - Profibus PASetup4 Setup4.1 Adjustment mediaAll VEGA Profibus sensors operate in profile3 and can be adjusted with:- the

Page 22 - Screening

Capacitive electrodes EK - Profibus PA 29If all sensors are already connected to thebus line, the address must be adjusted viaVEGACONNECT 3, the adjus

Page 23 - Ex protection

Capacitive electrodes EK - Profibus PA 3ContentsContentsSafety information ... 2N

Page 24 - 31.25kHz

30 Capacitive electrodes EK - Profibus PASetup4.2 Adjustment with the adjustmentmodule MINICOMAs with the PC, the sensor can also beadjusted with the

Page 25 - CAP E34 PA Ex

Capacitive electrodes EK - Profibus PA 31Arrow keys (5)With the keys > and <, you can move withinthe menu level from one menu item to theother.D

Page 26 - B62-30 W

32 Capacitive electrodes EK - Profibus PASetupApplication:- highly conductive products- adhesive, conductive products- solids with fluctuating moistur

Page 27

Capacitive electrodes EK - Profibus PA 33SetupKey DisplayAdjust-mentPara-meteradjustmentSensorm(d) 4.700OKOKwithmediumMin.adjustat %-------(Min. adju

Page 28 - 4.1 Adjustment media

34 Capacitive electrodes EK - Profibus PASetupAdd’lfunc-tionsInfoSensortypeCAPE34SerialnumberSoftw.Vers.SensorTa gmax.rangepFOffsetpFSensoraddr.Sensor

Page 29 - Adjustment with PDM

Capacitive electrodes EK - Profibus PA 35SetupMediumconductive Yesact.dist. m X,XXBolt print figures are sensor ormeasured value information andcann

Page 30 - Adjustment elements

36 Capacitive electrodes EK - Profibus PASensor Sensor Sensor SensorVVOSegmentcouplerProfibus PAcableProfibus DPinterface card(Softing)DP cableVVO con

Page 31 - 1. Sensor optimisation

Capacitive electrodes EK - Profibus PA 37First of all, click to "Profibus DP for PAsensors". Then choose the Profibus cardwhich is installed

Page 32 - Adjustment without medium

38 Capacitive electrodes EK - Profibus PAProfibus PA addressIn this window, you can assign a busaddress to the sensor in the field "Sensoraddress

Page 33 - 4. Outputs

Capacitive electrodes EK - Profibus PA 39Measurement loop descriptionIn this field, you can give your measurementloop a descriptive label, e.g. levelm

Page 34 - Non-conductive medium

4 Capacitive electrodes EK - Profibus PAProduct description1 Product description1.1 Function and configurationCapacitive electrodes series EK can dete

Page 35

40 Capacitive electrodes EK - Profibus PAFrom the window "Instrument data parameteradjustment", you can reach all submenus ofthe sensor. Jus

Page 36 - 4.3 Adjustment with VVO

Capacitive electrodes EK - Profibus PA 41SetupMax. adjustmentThere must be max. level in the vessel. If youpush the button Save, the output is set to

Page 37 - Configuration

42 Capacitive electrodes EK - Profibus PASetupIf you have chosen pF, you can assign acorresponding value in pF to the percentagevalue.Example0 % = 97,

Page 38 - Measuring system

Capacitive electrodes EK - Profibus PA 43Sensor paramter adjustment - OutputsIn this window, you can change the presetvalues for the PA output and the

Page 39

44 Capacitive electrodes EK - Profibus PASensor parameter adjustment - SensoroptimisationIn this window, the mode of the sensor canbe set. With this,

Page 40 - Sensor parameter adjustment

Capacitive electrodes EK - Profibus PA 45Confirm the question with OK, if theconditions are met.Display Diagnostics Instrument data Configuration Serv

Page 41

46 Capacitive electrodes EK - Profibus PADiagnosticsDisplay Diagnostics Instrument data Configuration Services Quit HelpStatusSimulationUnder the menu

Page 42

Capacitive electrodes EK - Profibus PA 47Under the menu item "Services" you canselect the following functions:• Print•View• Backup• Restore

Page 43 - Transfer

48 Capacitive electrodes EK - Profibus PASetupOperatorThis user level is for the operator. In thislevel, you can have the measured valuedisplayed and

Page 44 - "Scaling"

Capacitive electrodes EK - Profibus PA 49Diagnostics5 Diagnostics5.1 SimulationTo simulate a certain filling level, you can callup the function Simula

Page 45 - Correct

Capacitive electrodes EK - Profibus PA 5Product description1.2 Types and versionsType 1)EK EK EK EKVersion 11 21 24 31Continuous ••••Partly insulated

Page 46 - Simulation

50 Capacitive electrodes EK - Profibus PADiagnostics5.4 Failure rectificationFailure Measure, failure rectificationSensor defective, Test the internal

Page 47 - Services

Capacitive electrodes EK - Profibus PA 51DiagnosticsFailure Measure, failure rectificationContact 4 and vesselThe connection between contact 4 and the

Page 48 - Connection

52 Capacitive electrodes EK - Profibus PANotesFailure Measure, failure rectificationError messageError messageError messageError messageError message

Page 49 - 5 Diagnostics

Capacitive electrodes EK - Profibus PA 53Notes

Page 50 - 5.4 Failure rectification

54 Capacitive electrodes EK - Profibus PANotes

Page 51

Capacitive electrodes EK - Profibus PA 55Notes

Page 52

ISO 9001All statements relating to scope of delivery, application, practical useand operating conditions of the sensors and processing systemscorrespo

Page 53

6 Capacitive electrodes EK - Profibus PAProduct descriptionType 1)EK EK EK EKVersion 11 21 24 31Screening tube (option) stst • • •Temperature adapter(

Page 54

Capacitive electrodes EK - Profibus PA 7Product description1.3 Technical dataHousingHousing material Plastic PBT (Polyester) or Aluminiumplastic coate

Page 55

8 Capacitive electrodes EK - Profibus PAProduct descriptionAccessoryFixing spring of 1.4571- length approx. 185 mm (strained)- tensile force approx.

Page 56 - ISO 9001

Capacitive electrodes EK - Profibus PA 9+-0 %5 %10 %15 % vol.Product descriptionfully insulatedelectrodepartlyinsulatedelectrodesolidhumidity(%)Level

Commentaires sur ces manuels

Pas de commentaire