Operating InstructionsLock fitting ARV-VB67.2for VEGAVIB 67– pressure range -1 … 16 bar
10 Screw the pressure screw (11) with a view turns from topinto the mounting boss (7)11 Clean the connection tube of the sensor and the surfacesof the
6 Dismounting6.1 Dismounting procedureNote chapter "Mounting" and carry out the described steps inreverse order.Warning:If you want to remov
7 Supplement7.1 Technical dataGeneral dataMaterial 316L corresponds to 1.4404 or 1.4435Process fitting G2A or 2 NPTTube diameter of the sensor ø 43 mm
7.2 DimensionsLock fitting ARV-VB67.2 for VEGAVIB 67~ 75mm (2 61/64")20mm(25/32")ø 43mm(1 11/16")G2A/2NPT75mm(2 61/64")Fig. 2: Lock
14 Lock fitting ARV-VB67.2 -–pressure range -1 … 16 bar29756-EN-050804
Lock fitting ARV-VB67.2 -–pressure range -1 … 16 bar 1529756-EN-050804
VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermanyPhone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected] 9001All stateme
Contents1 About this document1.1 Function ...41.2 Target group ...41.3 Symbolism used ...
1 About this document1.1 FunctionThis operating instructions manual has all the information youneed for quick setup and safe operation of ARV-VB67.2.P
2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manualmust be carried out only by trained, specialise
3 Product description3.1 ConfigurationThe scope of delivery encompasses:l Lock fitting ARV-VB67.2 for VEGAVIB 67 vibrating levelswitchl Documentation- t
4 Mounting4.1 General instructionsThe note of the following general safety instructions:l Dismount the lock fitting only in unpressurized conditionl Us
7 Tighten the terminal screws (3) alternately. Make sure thatthe gap between clamp and pressure screw is in parallel.Tighten the terminal screws up to
17898101123456Fig. 1: Lock fitting ARV-VB67.2 - up to 16 bar (232 psi)1 Clamp2 Spring ring B83 Terminal screw M8 x 304 Locking angle5 Spring ring B46 H
5 Maintenance and fault rectification5.1 MaintenanceWhen used as directed in normal operation, lock fitting ARV-VB67.2 is completely maintenance-free.5.