Vega VEGASEL 643 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Vega VEGASEL 643. VEGA VEGASEL 643 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Level and Pressure
in
out
Operating Instruction
VEGASEL 643
12 43
56 78
9 1011121314
on
max.
min.
VEGASEL 643
++
6
5
++
3
5
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Operating Instruction

Level and PressureinoutOperating InstructionVEGASEL 64312 4356 789 1011121314onmax.min.VEGASEL 643––++65––++35

Page 2 - Contents

10 VEGASEL 643Set-up4 Set-up4.1 Indicating and operating elements1 Key for value falling2 Coded key for max. switch point3 Key for value raising4 Code

Page 3 - 1 Product description

VEGASEL 643 11Set-up• Mount the terminal socket.• Wire the input terminals of the terminal socket acc.to the above mentioned conditions.• Cover the in

Page 4 - 1.3 Types and versions

12 VEGASEL 643Set-upDouble point controlWith a double point control it is possible to generateswitching signals at two different points of the inputsi

Page 5 - Product description

VEGASEL 643 135.3 Failure removalFailure Removal / MeasureInstrument does notfunction, the greenmains control lampextinguishes Check the supply voltag

Page 6

14 VEGASEL 643Notes

Page 7 - Mounting

VEGASEL 643 15Notes

Page 8 - 3 Electrical connection

VEGA Grieshaber KGAm Hohenstein 113D-77761 SchiltachPhone (0 78 36) 50 - 0Fax (0 78 36) 50 - 201Fax (0 78 36) 50 - 203ISO 9001Technical data subject t

Page 9 - Electrical connection

2 VEGASEL 643ContentsSafety informationThe described module must only be inserted and oper-ated as described in this operating instruction. Pleasenote

Page 10 - 4 Set-up

VEGASEL 643 3Product description1 Product description1.1 Function and configurationVEGASEL 643 auxiliary level switch is a build-in instru-ment with t

Page 11 - 12 13 14

4 VEGASEL 643Product description1.3 Types and versionsVEGASEL 643Two-point auxiliary level switch with selectable mode; mode A (overfillprotection) or

Page 12

VEGASEL 643 5Product descriptionInput 3 1 voltage inputKind of input passive two-wire input analogRange 0/2 … 10 V DCInner resistor Ri ≥ 100 kΩApplica

Page 13 - 5 Diagnosis

6 VEGASEL 643Operating elementsFront plate 2 coded key0 … 99 %Laterally on top 1 DIL-switch for adjustment- mode A/B (overfill protection/protection a

Page 14 - 14 VEGASEL 643

VEGASEL 643 7MountingEach series 600 signal conditioning instrument con-sists of a terminal socket for carrier rail mounting DIN46 277 and a module i

Page 15 - VEGASEL 643 15

8 VEGASEL 64343+–12910+–L1+N –VEGASEL 64378+–10 V111213 143.2 Wiring planElectrical connection3 Electrical connection3.1 Wiring instructionThe follo

Page 16 - ISO 9001

VEGASEL 643 9Electrical connectionExtension example 1Instrument 1: VEGASEL 643 actively switchedInstrument 2 up to max. instrument 5: VEGASEL 643 pass

Commentaires sur ces manuels

Pas de commentaire